ZY-W-100溫濕度控制器
溫濕度控制器ZY -W - 100
The temperature and humidity controller ZY-W-100
一.主要功能The primary functions 帶一路溫度傳感器和一路凝露傳感器, 隨時監測環 境的溫濕度變化情況, 當濕度達到一定或溫度變化劇增 , 有產生凝露的可能時, 控制器驅動加熱器, 破壞產生 凝露的條件。當產生凝露的條件消失后, 加熱器自動斷 開, 控制器恢復到監測狀態。 The first temperature transducer and the dew sensor, always check to see the environmental changes in temperature or humidity, when the humidity got higher and higher,or the temperature is greatly changed and can run drew, the heater of controller to cause interference. when unfavourable factors disappeared, the heater automatic breaking-off and the state of being restored. 二.技術指標The technique index 1、供電電源:A C 2 3 0 V±1 0 %(6 0 H z) Power supplies: A C 2 3 0 V±1 0 %( 6 0 H z) 2、工作環境:溫度- 2 0℃ ~7 0℃濕度≤9 5 % R H Environment: temperature: - 2 0℃ ~7 0℃, humidity: ≤9 5 % R H 3、溫區控制范圍:5℃~2 0℃ The range of scream temperature: 5℃~2 0℃ 4、溫度控制精度:±1℃ The control precision: ±1℃ 5、濕度控制范圍:1 0 % R H~9 5 % R H 凝露啟控:≤9 5 % R H The range of humidity: 1 0 % R H~9 5 % R H drew arrested: ≤9 5 % R H 6、輸出接點:阻性A C 2 2 0 V,3 A Contact output: Resistive A C 2 2 0 V,3 A 7、功耗:≤2 W Consumption: ≤2 W 8、可靠安全性:符合I E C 8 3 4 - 1要求 Safety testing: Conform to I E C 8 3 4 - 1 9、外形尺寸:4 8×4 8×9 0 Overall dimensions:4 8×4 8×9 0 1 0、開孔尺寸:4 5×4 5 Perforation size: 4 5×4 5 三.安裝使用Installation 接線圖wiring diagram 面板式安裝 micropanel Installation 底座式安裝foundation installation 四.傳感器的安裝The Installation of transducer 1、凝露傳感器 The dew transducer (1)將傳感器兩則,用4 M固定在被測器件的殼體上。 The side of transducer was fixed in the shell with 4M (2)將傳感器插入導軌槽里。 The transducer put in single channel (3)溫度傳感器安裝方式與凝露傳感器相同 The way of temperature transducer installation is same to the dew sensor. (4)注:內置傳感器無需用戶安裝。 Note: The built-in transducer without user installation. 五、使用方法application 1、按圖接線,通電后,開啟指示燈亮,滿足加熱條件, 表示加熱器工作。 Follow the wiring diagram, the power has been turn on, the indicator lights up, meet the conditions for heating, and express the heater is normal work. 2、如需試驗凝露感濕后的加熱工作情況,在溫度大于 20度環境中,可將凝露傳感器放入冰箱約5分鐘后取出, 來模似凝露條件,或用對凝露傳感器哈氣的方法進行, 觀察凝露條件下的工作情況 If need to test the heating work when the drew feeling the dry ,in the environment if the environment temperature is high than 20℃,you can put the dew sensor in the refrigerator about five minutes to simulate drew conditions,or blew against the dew sensor, to observations work in the dew conditions. |
詳細說明 溫濕度控制器ZY - W - 1 0 0 The temperature and humidity controller ZY-W-100 一.主要功能The primary functions 帶一路溫度傳感器和一路凝露傳感器, 隨時監測環 境的溫濕度變化情況, 當濕度達到一定或溫度變化劇增 , 有產生凝露的可能時, 控制器驅動加熱器, 破壞產生 凝露的條件。當產生凝露的條件消失后, 加熱器自動斷 開, 控制器恢復到監測狀態。 The first temperature transducer and the dew sensor, always check to see the environmental changes in temperature or humidity, when the humidity got higher and higher,or the temperature is greatly changed and can run drew, the heater of controller to cause interference. when unfavourable factors disappeared, the heater automatic breaking-off and the state of being restored. 二.技術指標The technique index
1、供電電源:A C 2 3 0 V±1 0 %(6 0 H z) Power supplies: A C 2 3 0 V±1 0 %( 6 0 H z) 2、工作環境:溫度- 2 0℃ ~7 0℃濕度≤9 5 % R H Environment: temperature: - 2 0℃ ~7 0℃, humidity: ≤9 5 % R H 3、溫區控制范圍:5℃~2 0℃ The range of scream temperature: 5℃~2 0℃ 4、溫度控制精度:±1℃ The control precision: ±1℃ 5、濕度控制范圍:1 0 % R H~9 5 % R H 凝露啟控:≤9 5 % R H The range of humidity: 1 0 % R H~9 5 % R H drew arrested: ≤9 5 % R H 6、輸出接點:阻性A C 2 2 0 V,3 A Contact output: Resistive A C 2 2 0 V,3 A 7、功耗:≤2 W Consumption: ≤2 W 8、可靠安全性:符合I E C 8 3 4 - 1要求 Safety testing: Conform to I E C 8 3 4 - 1 9、外形尺寸:4 8×4 8×9 0 Overall dimensions:4 8×4 8×9 0 1 0、開孔尺寸:4 5×4 5 Perforation size: 4 5×4 5 三.安裝使用Installation 接線圖wiring diagram 面板式安裝 micropanel Installation 底座式安裝foundation installation
四.傳感器的安裝The Installation of transducer 1、凝露傳感器 The dew transducer (1)將傳感器兩則,用4 M固定在被測器件的殼體上。 The side of transducer was fixed in the shell with 4M (2)將傳感器插入導軌槽里。 The transducer put in single channel (3)溫度傳感器安裝方式與凝露傳感器相同 The way of temperature transducer installation is same to the dew sensor. (4)注:內置傳感器無需用戶安裝。 Note: The built-in transducer without user installation. 五、使用方法application 1、按圖接線,通電后,開啟指示燈亮,滿足加熱條件, 表示加熱器工作。 Follow the wiring diagram, the power has been turn on, the indicator lights up, meet the conditions for heating, and express the heater is normal work. 2、如需試驗凝露感濕后的加熱工作情況,在溫度大于 20度環境中,可將凝露傳感器放入冰箱約5分鐘后取出, 來模似凝露條件,或用對凝露傳感器哈氣的方法進行, 觀察凝露條件下的工作情況 If need to test the heating work when the drew feeling the dry ,in the environment if the environment temperature is high than 20℃,you can put the dew sensor in the refrigerator about five minutes to simulate drew conditions,or blew against the dew sensor, to observations work in the dew conditions. |